We find out why your RCCB, ELCB or main switch keeps tripping and fix the cause, not just reset it. Repairs typically cost RM150 to RM400, and you get a fixed quote before work starts. We offer same-day visits across KL and Selangor, 8am to 10pm daily.

Price from
RM150
Service
Same day
Warranty
12 months
Power Tripping Repair by My Power Care KL

Signs you need power tripping repair

  • The RCCB trips every time it rains or during a heavy storm
  • Power goes off when you switch on the water heater or kettle
  • Tripping happens around the same time each night, often when the aircond starts
  • The RCCB will not stay up even with every MCB switched off
  • One MCB keeps dropping on the kitchen or bathroom circuit
  • Tripping started after renovation work or a new appliance
  • Your DB box still has an old ELCB or rewireable fuses

How much does power tripping repair cost in KL?

Our current prices for power tripping repair across Kuala Lumpur and Selangor (updated October 2026). You get a fixed quote on site before any work starts.

Power Tripping Repair prices
JobPrice (RM)
Fault finding and testing (first hour)per jobFrom RM150
Power tripping: find and fixper jobRM150 – RM400
RCCB / ELCB replacement (unit included)per unitRM250 – RM450
MCB replacementper breakerRM80 – RM150
Inspection visit (minimum charge)per visitFrom RM80

Prices include labour and standard materials (cable, trunking, standard switches and sockets) unless the item says otherwise. See the full price list.

What's included

  1. 1Check the DB box, breaker ratings and how circuits are split
  2. 2Insulation resistance test on each circuit to find the leaking one
  3. 3Isolate suspect appliances one by one (heater, fridge, outdoor lights)
  4. 4Fixed quote, then repair or replace the faulty part
  5. 5Retest the RCCB trip time with an RCD tester
  6. 612-month workmanship warranty on the repair

Why does my RCCB keep tripping?

An RCCB trips when current leaks to earth, usually 30mA or more on a home circuit. The leak is almost always one of four things: water in an outdoor light or socket, an appliance with a failing heating element, damaged cable insulation, or an RCCB worn out after 10–15 years.

If an MCB trips instead, that one circuit is overloaded or shorted. A kettle, air fryer and microwave on the same kitchen circuit is the most common cause we see.

Why does it only trip when it rains?

Water gets into porch lights, garden lights, outdoor sockets and the taped cable joints behind them. It is our most common call between October and January, especially in older terraces with outdoor fittings that have no proper IP rating.

The fix is usually an IP65 fitting, a sealed junction box and a separate breaker for the outdoor circuit. Then a wet garden light switches off the garden, not the fridge.

Can I just reset it and carry on?

Resetting once is fine. If it trips again within minutes or days, there is a leak somewhere. Never tape it up or bypass it, and do not swap a 30mA unit for a 100mA one to stop the nuisance. Malaysian rules require 30mA protection on socket circuits because it stops a shock from becoming fatal.

Areas we cover

Power Tripping Repair: common questions

Most tripping jobs cost RM150 to RM400, depending on how long the fault takes to find and what needs replacing. A new RCCB, unit included, is RM250 to RM450. You get a fixed quote before any repair starts.